Context

ADR 0074 gave the server one managed shutdown() and drew the ownership line at the process: “core never registers process signals. Apps wire signals explicitly”, and srvx runs with gracefulShutdown: false so nothing hidden listens.

That line is right and stays. What it did not anticipate is that “wire signals explicitly” is not a one-liner. shutdown() is idempotent and parses its options only on the first call, so the only way a later signal can influence a running chain is the AbortSignal handed to that first call. Every application therefore rewrites the same state machine, and the hand-written versions consistently miss these states:

  • A signal during asynchronous preparation. Stopping schedulers before shutdown() means there is a window with no chain and no controller yet; a signal arriving there is lost.
  • A rejected shutdown. shutdown() rejects on a phase failure, on a forced cleanup that itself failed, and with an AggregateError when both fail. The cached promise is cached rejected, and a chain nobody caught surfaces as an unhandledRejection.
  • A third signal. The first process.on suppresses the signal’s default disposition. Once the chain is already forced, further signals do nothing — so a process stuck on a resource outside the transport boundary can no longer be killed with anything short of SIGKILL, precisely when the operator is pressing Ctrl+C for the third time.

Decision

Ship bindProcessSignals(handle, options) in stitchkit/server (and stitchkit/node, which re-exports explicitly — it does not re-export server/index.ts).

The ownership line of ADR 0074 is preserved and made precise: the framework still registers no listener of its own. Binding is an explicit call, close() takes it back, and the module contains no process.exit — the exit code stays supervisor policy, set by the application in onComplete / onError.

The machine is idle → preparing → running → settled:

  • the AbortController is created before onShutdown, so a signal in the preparation phase is not lost — shutdown() accepts an already-aborted signal and takes its forced path;
  • a later signal aborts that controller — the same chain, never a second one. Signals delivered in the same turn as the first do not count: a supervisor that sends SIGINT and SIGTERM together must not collapse the declared grace period to zero. Duplicate names in signals are deduplicated for the same reason;
  • any signal after the force, or one arriving while onComplete still runs, removes the listeners and re-raises the signal so its default disposition applies;
  • failure is routed by phase, not flattened. A failing onShutdown is reported as prepare and the shutdown still runs — a failed preparation must not leave the server listening with nobody draining it. A failing onComplete is reported as complete while promise stays resolved, because the transport really did shut down. Only a failing shutdown() rejects the chain;
  • state is mutated before user callbacks run, and every callback is wrapped: a throwing onRepeatedSignal cannot swallow the force, and a callback that re-enters through a custom SignalSource finds the machine already advanced;
  • nothing escapes into a signal handler: run() is caught, the returned promise is internally observed, and an onError that itself throws is swallowed rather than crashing the process mid-shutdown.

Options are a plain interface, not a Zod schema: most of its fields are callbacks and one is an injected source, none of which Zod can meaningfully validate. Only the forwarded shutdown budgets are parsed — with ShutdownOptionsSchema.omit({ signal: true }). The type rejects a caller-supplied signal; at runtime the schema strips it, as Zod strips any extra key.

The signal source is injectable (SignalSource), following RunCliConfig, so the machine is testable without patching globals or writing a cast.

Consequences

  • A consumer’s shutdown wiring drops to one call, and the missed states are handled by construction.
  • The binding accepts Pick<ManagedServerHandle, 'shutdown'>, so a test fakes one method instead of a whole server.
  • One binding per handle; a second throws. The guard is released only while the binding is idle: closing a binding whose chain is already running keeps the handle claimed, because shutdown() parses its options once and would ignore a second binding’s AbortSignal while resolving its promise with the first chain’s result.
  • Escalation is best-effort, and says so. Re-raising the signal restores the default disposition only while nothing else in the process listens for it; a logger, a REPL or another binding would swallow it and the process would survive. The default source checks process.listenerCount and reports through onEscalationBlocked instead of promising a kill it cannot perform. The framework still refuses to call process.exit itself.
  • This does add runtime behaviour: the escalation path ends a process via process.kill(process.pid, signal), which nothing in the framework did before. Forcing by a second real signal is unchanged and stays proven by the existing Bun and Node signal subprocess stands.
  • The official starter keeps its hand-written wiring for now: its lane resolves the published Stitchkit range, so it can only adopt this after release.
  • SIGTERM cannot be listened for on Node/Windows; the default signal set is documented rather than special-cased.